Calibrating the AGIBOT X2: when and how

Short answer
Zero calibration re-establishes the mechanical zero position of the joints, so that encoder deviation is corrected. The robotfaq documentation collection describes this on the X2 Calibration page (version 1.0, 27 July 2026, for X2 Lite and X2 Ultra with software version 0.8 to 1.0): with a Windows computer, an ethernet cable and a calibration tool, and for the legs with positioning pins. The waist is calibrated at the factory. This procedure has not been confirmed by AgiBot itself.
In brief
- Zero calibration re-establishes the mechanical zero position of the joints and corrects encoder deviation.
- The procedure comes from the robotfaq documentation collection (X2 Calibration, version 1.0 of 27 July 2026) and applies to X2 Lite and X2 Ultra with software version 0.8 to 1.0.
- Required: a Windows computer, an ethernet cable of preferably 1 meter or longer and, for the legs, two 2 mm pins and one 3 mm pin.
- You calibrate head, arms and legs per module; the waist requires a special holder and is done at the factory.
- The source reports that the new tool has problems with the calibration of joints J6 and J7 of the arm.
- AgiBot's AimDK 1.1.0 documentation contains no calibration procedure for the user.
What calibration means here
The source calls it zero calibration: re-establishing the mechanical zero position of the joints. This corrects deviation in the encoders. This article follows the X2 Calibration page from the robotfaq documentation collection, version 1.0 of 27 July 2026, checked on 22 November 2026. The page mentions X2 Lite and X2 Ultra with software version 0.8, 0.9 and 1.0. The documentation collection is not an AgiBot domain, and the procedure is not in AgiBot's AimDK 1.1.0 documentation. Therefore, do not adopt the steps without having confirmed them with AgiBot or your supplier. For starting up the robot itself, see AGIBOT X2 startup.
What do you need?
| Item | Explanation according to the source |
|---|---|
| Computer | Windows computer or laptop with the calibration tool (NPI Toolbox, NPI_OSTP.exe) |
| Network cable | Ethernet cable, preferably 1 meter or longer |
| Pins | Two 2 mm pins and one 3 mm pin, for the legs only |
| IP address | Fixed IP address on the computer: 10.0.1.99 with subnet mask 255.255.255.0 for the X2 Ultra, 10.0.200.99 for the X2 Lite. For the X2 Lite, you also enter the robot's IP address in the software. |
| Aid | Optionally a patient lift or transfer aid to suspend the robot. Without a lift, you calibrate the limbs with the robot lying or sitting. |
How to look up a robot's IP address is described in finding the IP address of an AgiBot robot.
How it works
- Head: open the HeadZeroing module and stand behind the robot. Turn the head to the far right position, hold it and confirm with Enter. Do the same to the left. Close once progress is 100%.
- Arms: each arm has its own module (LeftArmZeroing, RightArmZeroing). You calibrate joints J1 through J5 one by one by moving them to the limit and the middle and confirming each time until the software shows 100% and "pass". The source reports that the new tool currently has problems with the calibration of J6 and J7 and that the development department is working on a solution.
- Legs: for each joint, you insert the pin into the positioning hole and move the joint back and forth. If the motor stays silent, the pin is seated correctly. Confirm with Enter, wait until 100% and remove the pin. For J3, you align the joint with J2 according to the figure in the source; no pin is mentioned for it.
- Waist: this requires a special waist holder. On site, that is difficult, so the robot must go to the factory for the waist.
Differences between the versions are in X2 Ultra or X2 EDU.
Sources: X2 Calibration, version 1.0 from the robotfaq documentation collection (27 July 2026) and the AimDK X2 1.1.0 documentation. Checked on 22 November 2026.
Sources
- robotfaq documentation collection: X2 Calibration, version 1.0 (27 July 2026) (checked on 2026-11-22)
- AgiBot AimDK X2 1.1.0: table of contents (only factory calibration of the coordinate system mentioned) (checked on 2026-11-22)
Frequently asked questions
What does zero calibration do?
According to the source, you re-establish the mechanical zero position of the joints. That corrects deviation of the encoders and is meant to ensure motion accuracy and safety.
Which robots and versions does the procedure apply to?
The source mentions X2 Lite and X2 Ultra and software versions 0.8, 0.9 and 1.0. For a different version, check whether the procedure still applies.
How often do I need to calibrate the X2?
The source we read gives no fixed interval and no trigger. Ask your supplier or AgiBot.
Can I calibrate the whole robot myself?
The source describes head, arms and legs per module. The waist requires a special holder and is done at the factory.
What if a step in the calibration fails?
For joint J1 of the arm, the source says to repeat the steps. For the other joints it does not say so separately. For J6 and J7, the source reports known problems with the new tool.
Does AgiBot itself have a calibration manual for the X2?
In the AimDK 1.1.0 documentation, we found only the headings on factory calibration of the coordinate system, without content. We did not find a calibration procedure for users there.