Starting up the AGIBOT X2 for the first time: from box to walking

Short answer
Insert a battery with more than 50% charge, briefly press the power button on the battery and then hold it for 5 seconds. Wait about a minute, lay the robot on its back with arms and legs straight, and on the controller briefly press up arrow plus triangle to make it stand up. This is how AgiBot describes it in the AimDK 1.1.0 documentation for the X2 Ultra. If the robot has an OmniHand or gripper, standing up from lying on its back is not supported.
In brief
- The procedure below is in AgiBot's AimDK 1.1.0 documentation for the X2 Ultra and its new version. The X2 EDU follows a different procedure.
- Start only with a battery of more than 50%: briefly press the power button on the battery and then hold it for 5 seconds.
- After switching on, wait about a minute before operating the robot.
- Standing up from lying on its back is done with up arrow plus triangle; then walk with the left joystick and turn with the right.
- With an OmniHand or gripper, standing up from lying on its back is not supported.
- AgiBot also describes starting up hanging from a gantry (recommended when using the SDK) and from a seated position.
Before you begin
The steps come from the Startup Guide of AgiBot's AimDK 1.1.0 documentation, checked on 22 November 2026. They apply to the X2 Ultra and its new version; the X2 EDU follows a different procedure (see X2 Ultra or X2 EDU).
- Use a flat, hard surface without a slope.
- Start only with a battery of more than 2 bars, so more than 50%.
- The Agibot Go app is the accompanying app for connecting the robot, via Wi-Fi or AP hotspot. AgiBot states that the latest app version must match the latest firmware.
Step by step: starting up from lying on its back
This method does not require a gantry.
| Step | What you do |
|---|---|
| 1. Unpacking | Carefully lift the robot out of the packaging to avoid collisions. Position it so that you can insert or check the battery. |
| 2. Inserting the battery | Slide the battery into the slot at the back until you hear a click and check that it is secure. |
| 3. Switching on | Briefly press the power button on the battery and then hold it for 5 seconds. Within 2 seconds, LED 1 to 4 of the battery light up one after the other. |
| 4. Waiting | Wait about 1 minute without operating the robot. |
| 5. Lying on its back | Lay the robot face up, arms and legs straight. It is then in zero-torque mode. The hips point forward. |
| 6. Checking the space | Keep a clear radius around the robot (see the FAQ for 0.5 or 1 meter). |
| 7. Standing up | On the controller, briefly press up arrow plus triangle. The robot goes to stable standing. |
| 8. Walking | Left joystick: walking direction. Right joystick: turning on the spot. |
Other start methods
- Hanging from a gantry: AgiBot calls this the recommended method when using the SDK. After waiting about a minute, you lower the robot until both feet touch the ground and use L2 + X and then R2 + X for standby and stable standing.
- From a seated position: on a chair with a backrest 35 to 40 cm high, with an operator holding the rear handle. The combinations are up arrow + X and up arrow + square.
All combinations are in AGIBOT X2 controller buttons.
Please note
- Do not let the robot stand up from lying on its back if it has an OmniHand or gripper fitted. AgiBot does not support that.
- If the controller does not respond, read re-pairing the controller. According to AgiBot, the controller is paired from the factory.
Sources: Startup Guide, Robot Mobile App Connection, Remote Controller Connection (AimDK X2 1.1.0) and X2 Quick Start Guide v1.0 from the robotfaq documentation collection (8 June 2026). Checked on 22 November 2026.
Sources
- AgiBot AimDK X2 1.1.0: Startup Guide (checked on 2026-11-22)
- AgiBot AimDK X2 1.1.0: Robot Mobile App Connection (checked on 2026-11-22)
- AgiBot AimDK X2 1.1.0: Remote Controller Connection (checked on 2026-11-22)
- robotfaq documentation collection: X2 Quick Start Guide v1.0 (8 June 2026) (checked on 2026-11-22)
Frequently asked questions
How long does startup take?
AgiBot states waiting about 1 minute after switching on, without operating the robot. The robot is then in zero-torque mode, in which the joints are not driven.
Can I operate the X2 without an app?
AgiBot describes standing up from lying on its back and walking with the controller. You use the Agibot Go app to connect the robot, via Wi-Fi or AP hotspot.
On what surface may the X2 start up?
AgiBot specifies a flat, hard surface without a slope. The robotfaq documentation collection also mentions no steps and no loose carpet.
How much free space do I need?
The AimDK documentation specifies a clear radius of 0.5 meters around the robot before standing up from lying on its back begins. The quick start in the robotfaq documentation collection specifies 1 meter. Use the larger figure.
May the robot stand up from lying on its back with an OmniHand or gripper?
No. AgiBot says that standing up from a lying position is then not supported, to prevent damage to the hardware.
Does this also apply to the X2 EDU?
No. AgiBot's startup page applies to the X2 Ultra and its new version and states that the X2 EDU follows a different procedure. See the difference in X2 Ultra or X2 EDU.
Which software version do these steps belong to?
The steps come from the AimDK 1.1.0 documentation. According to AgiBot, the latest app version must match the latest firmware of the robot. For a different version, check the documentation that belongs to it.